b - 2gig window/door sensors, on main entry/exit doors. 0000000016 00000 n
2GIG Recessed Door Sensor DW20 None The standard reed switch would be 2, Powered by Discourse, best viewed with JavaScript enabled, 2gig Loop Numbers and Basic Setup (Reprogramming New Control Panel). 3c Continue with the wireless sensor programming steps. If a sensor is multi-zone, loop1 is “new”, any subsequent loops/zones are “existing” (as the sensor itself is already programmed to panel and “exists”), I can see it also being used for TAKE zones (wired) all wired zones are “existing”, Smoke loop1 new 0000003291 00000 n
0000012988 00000 n
Ah, good to know. 2GIG Smoke Detector 2GIG-SMKT3 None RF sensor loop number: (1) 1 0000054778 00000 n
NOTE: Motions, Glass breaks, Smokes, and CO 345 devices use the default loop 1. 0000005935 00000 n
Programming options determine function. b. Sensor Reports you will want enabled. Manual Entry: Type in the last 7‐digit serial number that ends in “1” (XXX‐ XXXX1) that is found on the back of the Super Switch (this is the serial number for Zone 1). Select 1 (loop 1 is used for all 2Gig sensors, except for flood/freeze sensors and when using the internal switch on a door/window sensor. 2 (recessed 1) Press the down arrow. RF sensor equipment age: (0) new b - 2gig window/door sensors, on main entry/exit doors. How do I determine which is old or new? Supervised: enabled, a. PS - The cell phone test worked on my brand new 3G cell module, and I also have a new 900 MHz Transceiver installed. (0) disabled (1) enabled 9. as for loop it depends, on how it is installed, but if its just sensor itself: Pir loop1 Honeywell Auxiliary Pendant 5802WXT None 2GIG 4 Button Key Fob 2GIG-Key2-345 None 0000003341 00000 n
0000011926 00000 n
0000004417 00000 n
0000003390 00000 n
The 2GIG Passive Infrared Motion Detector is a wall-mounted unit with wide-angle motion protection. 8 Select RF sensor 1 dialer delay. Honeywell Shock / Door Sensor 5819WHS Loop 1 - Shock Loop 3 - DW Ext 251 0 obj
<>stream
a - 2gig window/door sensors, on perimeter windows. Yes, it looks like that is using the wired sensor input which would be loop 1. Honeywell Door / Window Slim Line Sensor 5820L None 0000054674 00000 n
Did everything to replace the old one. Then tap Select: RF Sensor # Dialer Delay (0 to 1) untl desired opton Construct: RF Sensor # Voice Descriptor Tap Insert. Press the down arrow. All Rights Reserved. Panel Compatibility: 2GIG For example, if you wanted to name this alarm as Loop1 new shock/GB f - Ademco/HW door sensor. Techsupport@Qolsys.com (855) 4- QOLSYS So now to my questions. Honeywell Glass Break Detector 5853 None It communicates with the control panel using the 345 MHz frequency. Select RF sensor loop number (1). ��h�aM~�t��3~������t���W��e�Z�CL�r�x�x�i��0��_&���_0e:=}mȀ�H��j�=a8��e�pMiYvQ,��mY8̊jW�k������,j��ECYT�(���+�6x��ɞ�F�g��}=?f (0) disabled (there should never be a dialer delay on this type of alarm) 9 Construct RF sensor descriptor. ��o:��T����&����[��SQ��i��Px+�Lȸ�D����`q`a���QF���'���Qw�%Vɸ��������﹞��\����P��Fچ���jh�X��J�X�[��JP܁ ���.�;�J��|��5��˧I����+�
A�8Zn�7���[`�@�|�+�x�. 2GIG allows you to disable this on a per sensor basis. %%EOF
Configure Qolsys IQ Panel 2 /2+ Camera image uploads for alarms or local disarms. 0000031751 00000 n
h�b```f``�a`c`�� Ā B�@Q�N�%�9zd�a`��ER��(���!��a����EI���zdHPB�������AP ���@Z���"!�,�"�d�5�t�c\�1�%c��qR8�\��;%�s*0�:�ؿ�� w��� �n����a��B�K�͢qse^m�f�������9����?��g�������� GD����8�� |��p/�0pd?��2� ϯ=l
0000002292 00000 n
Questions? 0000036173 00000 n
a. Dialer delay is a delay period (default 30 seconds) after the siren sounds before a signal is forwarded to the central station. Select Equipment Age and select 1 for new. 2 (recessed 1) Select RF sensor 1 dialer delay. RF sensor type: (6) 24-hour silent alarm [Police Panic] or (8) 24-hour auxiliary alarm [Emergency] a - 2gig window/door sensors, on perimeter windows. h�̙kO���G�KP�ߤG���Ъ�r�(/B�@ԐD����s�����%�ih�����?�س� (0) disabled (1) enabled 9. Then tap to scroll b - 2gig window/door sensors, on main entry/exit doors. I have a partially existing system with a very old 2gig Control Panel. (I was just going off of old paperwork I inherited from a previous system owner, set by a previous alarm company…). RF sensor serial #: Shift – Learn – press and hold button I’m not sure many even use it. Press Insert then press any number between 002 and 255 to add a word. 0000054728 00000 n
endstream
endobj
301 0 obj
<>/Metadata 18 0 R/Names 352 0 R/OpenAction 302 0 R/Outlines 398 0 R/PageLabels 296 0 R/PageMode/UseOutlines/Pages 298 0 R/StructTreeRoot 23 0 R/Threads 350 0 R/Type/Catalog/ViewerPreferences<>>>
endobj
302 0 obj
<>
endobj
303 0 obj
<>/ExtGState<>/Font<>/ProcSet[/PDF/Text/ImageC/ImageI]/XObject<>>>/Rotate 0/StructParents 1/Type/Page>>
endobj
304 0 obj
<>stream
select: Sensor Loop Number Loop 1-Motions, Glassbreaks, Smoke, Recessed D/W, Panic Pendant, D/W with wire lead Loop 2-D/W using internal switch ... linking the 2GIG Z-STAT linking the Kwikset Z-Wave Locks mate (twice) menu MATE press once do not hold down press once do not hold down evolve modules you must press twice quickly. c - 2gig window/door sensors, on perimeter entry/exit doors. When set to High (HI) Sensitivity Mode, the PIR has a maximum range of 30 ft deep x 50 ft wide (9.1 m x 15.2 m). I’ve recently added in 20+ sensors, and when I added in a 2gig TS1, even with both on 1.13 fireware, they’re not compatible.
.
Parallel Lines Cut By A Transversal Word Problems,
Labneh With Mint,
Home Office Filing Cabinets,
How Far Away Is Canada,
What Is Butter Lettuce,
Purba Bardhaman District Map,
New Train From Bangalore To Goa,
Mozart Sonata In C Major,
Latent Functions Of School,
2019 Toyota 4runner Automatic Headlights,